GEAR MOTOR MR 737 35Q

MR73735Q

MR73735Qf

MR73735Q 2

MR73735Qf 2

 

TYPE

 Ratio  L
mm

 Efficiency

%

R.P.M.

No load
*min-1 

Ampere

S1

 R.P.M. S 1
*min-1
Torque S1
Nm 

Ampere

 S2

R.P.M. S2
*min-1 
Torque S2
Nm 

Ampere I Max

 Nmax

torque Nm

MR 737 H 35Q 16 104 82 440 1 408 0,25 2 360 0,65 10 3,5
MR 737 S 35Q 16 104 82 310 1 265 0,43  1,7 220 0,85 5,5 3
MR 737 L 35Q 16 104 82 165 0,35 140 0,22 0,55 118 0,43 1,6 1,5
MR 737 H 35Q  64  113 73  110 1  102  0,86 2  90  2,1 10  12
MR 737 S 35Q  64  113 73  80 1 68  1,43  1,7  57  2,8 5,5  10
MR 737 L 35Q 64  113  73  40 0,35  35  0,7 0,55  28  1,43 1,6  5
MR 737 H 35Q  256  121 65  28 1  26  3 2  23  7,5 3,5  15
MR 737 H 35Q L  256  130 65  28 1  26  3 2,5  21  10 4,2  28
MR 737 S 35Q  256  121 65  20 1  17  5 1,7  14  10 2,4  15
MR 737 S 35Q L  256  130 65  20 1  17  5 2  13  12 4,5  28
MR 737 L 35Q  256  121 65  10 0,35  8  3 0,55  7  5,5 1,2  15
MR 737 L 35Q L  256  130 65 10  0,5  7,5  5 0,9  5  10 1,6  20
MR 737 S 35Q   1024 130  57  5 0,4  4,8  4,5 0,6  4,6  8,5 0,7  15
MR 737 L 35Q  1024   130 57  2,5 0,23  2,3  4,5 0,33 2,1   9,3 0,44  15

 

Lenght of the gearmotor as a function of reduction and the number of output turns. Motors 737 have powers 10 - 20 - 25 W, voltage 12 or 24 VDC (version 737 H only 24 VDC).
This data sheet refers to the version 24 VDC.
 
Output shaft is supported by two screened bearings. The motor and the reduction gear are both zinc plated for corrosion strength. Permanent greasing.
 
The motor has an electrical suppressor system for the CE standard. The speed rotation can change of +/- 10%.
Max forces which can act on the output shaft: Axial 300 N - Radial 400 N, on the extremity of the output shaft.
 
The S1 continuous load test was made in the air with an increase of temperature of 70° C.
The S2 intermittent (50% timing: 5'ON – 5'OFF) load test was made in the air an increase of temperature of 80° C.
The startig current (I max) must not be maintained for more than 2” (seconds).
 
It is possible to apply an our Encoder.

 

 

 

For further informations please contact our technical department.

 
 
 
 

Bernio Elettromeccanica s.n.c.